Product
Quality
Product Introduction
This 250 KVA transformer was delivered to Djibouti in 2015. the rated power of the transformer is 250 KVA. It is a Step-down transformer 11KV to 0.4KV, the primary voltage is 11kv, the secondary voltage is 400v. The transformer adopted copper wire as winding material,thus it have better mechanical strength and anti-short circuit ability than aluminum windings. Our 250 kVA Distribution Transformer was designed with advanced technology and adopts high quality material and components which result in reliable quality and long operation time.
SCOTECH ensure each one of our delivered transformers had passed the full acceptance test and we remains 0 fault rate record for more than 10 years so far, oil immersed power transformer is designed in accordance with IEC, ANSI and other major international standards.
Scope of Supply
Product: Oil Immersed distribution Transformer
Rated Power: Up to 5000 KVA
Primary Voltage: Up to 35 KV
Technical Specification
250 KVA transformer specification and load capacity.
Delivered to | Djibouti |
Year | 2015 |
Model | S11-250 KVA-11/0.4KV |
Type | Oil Immersed Distribution Transformer |
Standard | IEC60076 |
Rated Power | 250 KVA |
Frequency | 50HZ |
Phase | Three |
Cooling Type | ONAN |
Primary Voltage | 11KV |
Secondary Voltage | 0.4KV |
Winding Material | copper |
Vector Group | Dyn11 |
Impedance | 4% |
Tap Changer | NLTC |
Tapping Range | ±2*2.5% |
No Load Loss | 0.4KW |
On Load Loss | 3.05KW |
Accessories | Standard Configuration |
250 KVA Transformer Gas Relay
What is a gas relay?
The transformer gas relay is a protective device installed on the top of oil-filled transformers. It performs two functions. It detects the slow accumulation of gases, providing an alarm after a given amount of gas has been collected. ... An incipient fault or developing fault, usually causes slow formation of gas.
Finished 250 KVA 11/0.4KV Transformer
Why tap changer is placed on high voltage side?
The tap changer is placed on high voltage side because:
1) The HV winding generally wound over LV winding hence it is easier to access the HV winding turns instead of LV winding.
2) Because of high voltage the current through the HV winding is less compared to LV windings, hence there is less “wear” on the tap changer contacts. Due this low current, in on load tap changer the changeover spark will be less.
Packing and Delivery
FAQ
1. How soon can you delivery the transformer?
It depends on the quantity and capacity of the transformer, normally within one month since the date drawing confirmed by buyer.
2. How long can you provide the quality warranty?
12 months since the date transformer operated.
3. What payment method do you accept?
T/T (wire transfer), L/C both accepted.
Hot Tags: 250 kva 11kv power distribution transformer, China, suppliers, manufacturers, factory, price, cost, specifications, for sale, power distribution transformer 50kva, Liquid dielectric transformer 11kv, Dyn11 11kv distribution transformer, 25kv 0 4kv step down transformer, Three phase 750 KVA transformer, 150kva power distribution transformer
800 KVA 11KV To 550V Output Distribution Transform...
1.25 MVA 1250 KVA Dyn11 Power Supply Distribution ...
150 KVA 11KV 3 Phase Step Down and Step Up Distrib...
3MVA-6.6/0.525kV Oil Immersed Distribution Transfo...
1.6 MVA 1600 KVA 11KV Delta Star Distribution Tran...
225 KVA 11KV Power Distribution Transformer
keywords: